OPTIX cable Duct Z-XOTKtsdDb 96x9/125 8T12F ITU-T G.652D 3.0kN
Producent | Optix |
---|
OPTIX Cable DUCT Z-XOTKtsdDb 3.0kN
DUCT CABLE
9/125 ITU-T G.652D
- Fully dielectric construction
- Solid HDPE jacket
- Additional water blocking construction
- Resistance to high and low temperatures
- Enhanced by high quality glass yarns
- Practical and thin Ripcord
CABLE CONSTRUCTION
- FRP rod
- Optical fibres in 0.25mm coloured coating
- Hydrophobic jelly
- Loose tube
- Ripcords to tear the outer jacket
- Filler
- Water blocking tape / yarns
- Glass yarns
- HDPE outer jacket (black), UV stabilized
OPTIX DUCT Z-XOTKtsdDb (Glass yarns) cable: a light multi-tube construction, great flexibility and durability against dragging, a central strengthening element (FRP rod), gel and a water blocking construction (WB), moisture absorbing yarns (WSY) / anti-humidity tape, fully dielectric, strengthened with glass yarns, HDPE shell - UV radation resistant, temperature range between -40°C and +70°C - an equivalent to Z-XOTKtsdDb. Maximum installation tension: 3000N.
All fibres and tubes of the cable adhere to the "EIA/TIA-598" colour coding standard. Each tube containing up to 24 fibres is filed with a hydrophobic gel to protect against moisture and vibrations. The cable core is safeguarded against water penetration by moisture absorbing yarns or an anti-humidity tape. The cables tubes and filler elements are twisted along a central strengthening element - the FRP rod. Two threads molten into the cable shell (ripcords) ease the removal of the cables outer layer. The cables are meant for installation in primary and secondary tele-technical canalisation by pneumatic (cable blowing) and mechanical (cable pulling) methods.
Product information | ||||||||||
Cable version |
The total amount of fibres [pcs] |
Weight [kg/km] (±10%) |
∅ Cable [mm] (±0.5) |
∅ Tube [mm] (±0.15) |
Supporting element/ Peripheral reinforcement |
Reinforcing element [mm] (±0.1) |
Coating material & thickness [mm] (±0.2) |
Temp. range instalation |
Temp. range operating transport |
Minimum bending radius temporary permanent |
1T12F | 12 | 85 | 10.1 | 1.4/2.0 | Glass yarns | FRP(2.25) | HDPE(1.5) | -5° to +40°C | -40° to +70°C | 20D/15D |
2T6F | 12 | 85 | 10.1 | 1.4/2.0 | Glass yarns | FRP(2.25) | HDPE(1.5) | -5° to +40°C | -40° to +70°C | 20D/15D |
2T12F | 24 | 85 | 10.1 | 1.4/2.0 | Glass yarns | FRP(2.25) | HDPE(1.5) | -5° to +40°C | -40° to +70°C | 20D/15D |
4T6F | 24 | 85 | 10.1 | 1.4/2.0 | Glass yarns | FRP(2.25) | HDPE(1.5) | -5° to +40°C | -40° to +70°C | 20D/15D |
4T12F | 48 | 85 | 10.1 | 1.4/2.0 | Glass yarns | FRP(2.25) | HDPE(1.5) | -5° to +40°C | -40° to +70°C | 20D/15D |
6T12F | 72 | 85 | 10.1 | 1.4/2.0 | Glass yarns | FRP(2.25) | HDPE(1.5) | -5° to +40°C | -40° to +70°C | 20D/15D |
8T12F | 96 | 110 | 11.4 | 1.4/2.0 | Glass yarns | FRP in PE coat(2.5/3.5) | HDPE(1.5) | -5° to +40°C | -40° to +70°C | 20D/15D |
12T12F | 144 | 160 | 14.0 | 1.4/2.0 | Glass yarns | FRP in PE coat(3.5/6.0) | HDPE(1.5) | -5° to +40°C | -40° to +70°C | 20D/15D |
16T12F | 192 | 160 | 14.0 | 1.4/2.0 | Glass yarns | FRP(2.25) | HDPE(1.5) | -5° to +40°C | -40° to +70°C | 20D/15D |
18T12F | 216 | 160 | 14.0 | 1.4/2.0 | Glass yarns | FRP(2.25) | HDPE(1.5) | -5° to +40°C | -40° to +70°C | 20D/15D |
24T12F | 288 | 210 | 15.8 | 1.4/2.0 | Glass yarns | FRP in PE coat(3.0/4.0) | HDPE(1.5) | -5° to +40°C | -40° to +70°C | 20D/15D |
Mechanical parameters | EN standard | IEC standard | 1-24F | 48F | 72F | 96-288F |
Tensile Strength Installation | EN 187000 | IEC 60794-1-2-E1 | 3000N | 3000N | 3000N | 3000N |
Tensile Strength Operation | EN 187000 | IEC 60794-1-2-E1 | 2000N | 2000N | 2000N | 2000N |
Crushing resistance | EN 187000, m.504 | IEC 60794-1-2-E3 | 2000N (100x100mm) for 60 sec. | |||
Repeated bending | EN 187000, m.507 | IEC 60794-1-2-E6 | 30 cycles [(20xD), 1kg] |
Producent | Optix |
---|