OPTIX MICRO Z-XOTKtmd MC301 0.65-1.0kN
Zaczynając od 2,47 zł 2,01 zł
OPTIX Cable MICRO Z-XOTKtmd MC301 0.65-1.0kN 9/125 ITU-T G.652D
MICRODUCT CABLE
- Cable for microduct installation
 - Solid HDPE jacket
 - Small reduced diameter
 - Designed to cable blowing
 - Water blocking construction
 - Reinforced by FRP central Strengyh member
 - Resistance to high and low temperatures
 - Fully dielectric construction
 
CABLE CONSTRUCTION
- FRP rod
 - Optical fibres in 0.25mm coloured coating
 - Loose tube
 - Water blocking yarns
 - Ripcords to tear the outer jacket
 - Hydrophobic jelly
 - Filler
 - HDPE outer jacket (black), UV stabilized
 
OPTIX MICRO Z-XOTKtmd MC301 cable are a family of distributive micro-canalisation cables for micro-tubes of an internal diameter of up to 8mm (for 12 - 92 fibres), 10mm (for 144 fibres). A light small diameter construction, strengthened with a fibreglass rod, (0.5mm) HDPE coating, installation tension strength: 650-1000N, temperature range between -20°C and + 70°C - an equivalent to Micro Z-XOTKtmd.
All cable fibres and tubes adhere to the "EIA/TIA-598" colour coding standard. Each tube is filled with hydrophobic gel for anti-moisture and anti-vibration fibre protection. The cables are meant for installation in primary and secondary tele-technical canalisation by pneumatic (blow-in) methods.
![]()  | 
| Product information | ||||||||||
| Cable version  | 
		The total amount of fibres [pcs]  | 
		Weight [kg/km] (±10%)  | 
		∅ Cable [mm] (±0.3)  | 
		∅ Tube [mm] (±0.1)  | 
		Supporting element/ Peripheral reinforcement  | 
		Reinforcing  element [mm] (±0.1)  | 
		Coating material & thickness [mm] (±0.1)  | 
		Temp. range instalation  | 
		Temp. range operating transport  | 
		Minimum  bending radius temporary permanent  | 
		
	
| 2T6F | 12 | 26 | 5.4 | 1.15/1.45) | None | FRP 1.60 | HDPE(0.5) | -10° to +50°C | -30° to +70°C | 20D/10D | 
| 1T12F | 12 | 26 | 5.4 | 1.15/1.45) | None | FRP 1.60 | HDPE(0.5) | -10° to +50°C | -30° to +70°C | 20D/10D | 
| 2T12F | 24 | 26 | 5.4 | 1.15/1.45) | None | FRP 1.60 | HDPE(0.5) | -10° to +50°C | -30° to +70°C | 20D/10D | 
| 4T6F | 24 | 26 | 5.4 | 1.15/1.45) | None | FRP 1.60 | HDPE(0.5) | -10° to +50°C | -30° to +70°C | 20D/10D | 
| 3T12F | 36 | 26 | 5.4 | 1.15/1.45) | None | FRP 1.60 | HDPE(0.5) | -10° to +50°C | -30° to +70°C | 20D/10D | 
| 4T12F | 48 | 26 | 5.4 | 1.15/1.45) | None | FRP 1.60 | HDPE(0.5) | -10° to +50°C | -30° to +70°C | 20D/10D | 
| 6T12F | 72 | 26 | 5.4 | 1.15/1.45) | None | FRP 1.60 | HDPE(0.5) | -10° to +50°C | -30° to +70°C | 20D/10D | 
| 8T12F | 96 | 36 | 6.1 | 1.15/1.45) | None | FRP 2.4 | HDPE(0.5) | -10° to +50°C | -30° to +70°C | 20D/10D | 
| 12T12F | 144 | 52 | 7.9 | 1.15/1.45) | None | FRP in PE coat (2.4/4.1) | HDPE(0.5) | -10° to +50°C | -30° to +70°C | 20D/10D | 
| 24T6F | 144 | 80 | 9.3 | 1.15/1.45) | None | FRP 2.80 | HDPE(0.5) | -10° to +50°C | -30° to +70°C | 20D/10D | 
| 16T12F | 192 | 52 | 7.9 | 1.15/1.45) | None | FRP 1.60 | HDPE(0.5) | -10° to +50°C | -30° to +70°C | 20D/10D | 
| 18T12F | 216 | 52 | 7.9 | 1.15/1.45) | None | FRP 1.60 | HDPE(0.5) | -10° to +50°C | -30° to +70°C | 20D/10D | 
| 24T12F | 288 | 80 | 9.3 | 1.15/1.45) | None | FRP 2.80 | HDPE(0.5) | -10° to +50°C | -30° to +70°C | 20D/10D | 
| Mechanical parameters | EN standard | IEC standard | 12-72F | 96-144F | 192-216F | 288F | 
| Tensile Strength Installation | EN 187000 | IEC 60794-1-2-E1 | 650N | 800N | 650N | 1000N | 
| Tensile Strength Operation | EN 187000 | IEC 60794-1-2-E1 | 450N | 550N | 450N | 700N | 
| Crushing resistance | EN 187000, m.504 | IEC 60794-1-2-E3 | 500N (100x100mm) for 60 sec. | |||
| Repeated bending | EN 187000, m.507 | IEC 60794-1-2-E6 | 25 cycles(20xD) | |||