OPTIX LSZH ZW-NOTKtsd 1.2kN
A partire da 0,93 € 0,76 €
OPTIX Cable LSZH ZW-NOTKtsd 1.2kN
UNIVERSAL INDOOR/OUTDOOR CABLE
9/125 ITU-T G.652D
- Fully dielectric construction
- Solid LSZH jacket
- Additional water blocking construction
- Resistance to high and low temperatures
- Practical and thin Ripcord
CABLE CONSTRUCTION
- FRP rod
- Optical fibres in 0.25mm coloured coating
- Hydrophobic jelly
- Loose tube
- Ripcords to tear the outer jacket
- Filler
- Water blocking tape / yarns
- LSZH outer jacket (black)
OPTIX LSZH ZW-NOTKtsd cable: a lightweight multi-tube construction, great flexibility and durability against dragging, a central strengthening element (FRP rod), gel and a water blocking construction (WB), moisture absorbing yarns (WSY) and anti-humidity tape fully dielectric, black LSZH coating - UV radation resistant, temperature range between -40°C and +70°C - equivalent to ZW-NOTKtsd. Maximum installation tension: 1200N.
All fibres and tubes of the cable are colour coded according to the "EIA/TIA-598" standard. Each tube containing up to 12 fibres (up to 24 for the 288J) is filed with hydrophobic gel which protect them against moisture and vibration. The core of the cable is safeguarded against water penetration by moisture absorbing yarns and anti-humidity tape. The cables tubes as well as filler elements are twisted along the central strengthening element - the FRP rod. Two threads molten into the coating (ripcords) ease the removal of the cables outer layer. The use of a non-flammable, non-halogen outer shell provides resistance to flame spreading. The cables can be used both inside, as well as outside of buildings, or building constructions. The are meant for installation in closed areas, tunnels, in tele-technical primary and secondary canalisation by pneumatic (cable blowing) and mechanical (cable pulling) means.
Product information | ||||||||||
Cable version |
The total amount of fibres [pcs] |
Weight [kg/km] (±10%) |
∅ Cable [mm] (±0.5) |
∅ Tube [mm] (±0.2) |
Supporting element/ Peripheral reinforcement |
Reinforcing element [mm] (±0.1) |
Coating material & thickness [mm] (±0.2) |
Temp. range instalation |
Temp. range operating transport |
Minimum bending radius temporary permanent |
2T6F | 12 | 105 | 10.2 | 1.4/2.0 | None | FRP(2.0) | LSZH (1.6) | -40° to +60°C | -40° to +70°C | 20D/10D |
4T6F | 24 | 105 | 10.2 | 1.4/2.0 | None | FRP(2.0) | LSZH (1.6) | -40° to +60°C | -40° to +70°C | 20D/10D |
4T12F | 48 | 105 | 10.2 | 1.4/2.0 | None | FRP(2.0) | LSZH (1.6) | -40° to +60°C | -40° to +70°C | 20D/10D |
6T12F | 72 | 105 | 10.2 | 1.4/2.0 | None | FRP(2.0) | LSZH (1.6) | -40° to +60°C | -40° to +70°C | 20D/10D |
8T12F | 96 | 130 | 11.5 | 1.4/2.0 | None | FRP(2.0) | LSZH (1.6) | -40° to +60°C | -40° to +70°C | 20D/10D |
12T12F | 144 | 195 | 14.2 | 1.4/2.0 | None | FRP(2.0) | LSZH (1.6) | -40° to +60°C | -40° to +70°C | 20D/10D |
12T24F | 288 | 250 | 16.5 (±1.0) | 1.4/2.0 | None | FRP(2.0) | LSZH (1.6) | -40° to +60°C | -40° to +70°C | 20D/10D |
Mechanical parameters | EN standard | IEC standard | 12-24F | 48F | 72F | 96-288F |
Tensile Strength Installation | EN 187000 | IEC 60794-1-2-E1 | 1200N | 1200N | 1200N | 1200N |
Tensile Strength Operation | EN 187000 | IEC 60794-1-2-E1 | 500N | 500N | 500N | 500N |
Crushing resistance | EN 187000, m.504 | IEC 60794-1-2-E3 | 2000N (100x100mm) for 60 sec. | |||
Repeated bending | EN 187000, m.507 | IEC 60794-1-2-E6 | 25 cycles (20xD) |