OPTIX FRP Z-XOTKtcd ITU-T G.652D 1.2kN (SPAN 35m) 4km REEL
A partire da 1,60 € 1,30 €
OPTIX Optical Fiber Cable FRP Z-XOTKtcd 1.2kN 9/125 ITU-T G.652D RELL
OPTIX FRP Z-XOTKtcd cable: a light single-tube construction (40-50kg/km), great flexibility and durability against dragging , diameter of 6.5-7.0mm, gel and water blocking construction (WB), HDPE coating, UV-ray resistant, temperature range of -40°C - 70°C, reinforced with 2 FRP (∅0.9mm) rods, wholly dielectric - Z-XOTKtcd equivalent. Maximum installation tension: 1200N.
All cable fibres are colour coded according to the "EIA/TIA-598" standard. The tube consists of up to 24 fibre-optical threads and is filled with a hydrophobic gel for protecting the threads against moisture and vibrations. The centre of the cable is guarded against water penetration by swellable yarns. For additional construction durability two FRP rods have been molten into the outer HDPE layer of the cable easier. The cables are meant for installation in primary and secondary tele-technical canalisation by pneumatic (cable blowing) and mechanical (cable jetting) means, as well as for aerial installation on a span of up to 35m.
Features
- Universal cable for aerial/canalization installation
- Span (NESC Heavy) up to 35 meters (1.2kN)
- Fully dielectric construction
- Resistance to high and low temperatures
- Water blocking construction
- Solid HDPE jacket
Cable construction
- Optical fibres in 0.25mm coloured coating
- Loose tube
- Ripcords to tear the outer jacket
- FRP rods
- HDPE outer jacket (black), UV stabilized
- Water blocking yarns
Technical specification
Product information | ||||||||||
Cable version |
The total amount of fibres [pcs] |
Weight [kg/km] (±10%) |
∅ Cable [mm] (±0.5) |
∅ Tube [mm] (±0.15) |
Supporting element/ Peripheral reinforcement |
Reinforcing element [mm] (±0.1) |
Coating material & thickness [mm] (±0.2) |
Temp. range instalation |
Temp. range operating transport |
Minimum bending radius temporary permanent |
1T4F | 4 | 40 | 6.5 | 1.4/2.0) | None | FRP(2x0.9) | HDPE(2.0) | -10° to +50°C | -40° to +70°C | 20D/15D |
1T8F | 8 | 40 | 6.5 | 1.4/2.0) | None | FRP(2x0.9) | HDPE(2.0) | -10° to +50°C | -40° to +70°C | 20D/15D |
1T12F | 12 | 40 | 6.5 | 1.4/2.0) | None | FRP(2x0.9) | HDPE(2.0) | -10° to +50°C | -40° to +70°C | 20D/15D |
1T24F | 24 | 50 | 7.0 | 1.6/2.4) | None | FRP(2x0.9) | HDPE(2.0) | -10° to +50°C | -40° to +70°C | 20D/15D |
Mechanical parameters | EN standard | IEC standard | 1-8F | 12F | 24F |
Tensile Strength Installation (NESC Heavy) | EN 187000 | IEC 60794-1-2-E1 | 1200N | 1200N | 1200N |
Tensile Strength Operation (NESC Heavy) | EN 187000 | IEC 60794-1-2-E1 | 600N | 600N | 600N |
Crushing resistance | EN 187000, m.504 | IEC 60794-1-2-E3 | 500N (100x100mm) for 60 sec. | ||
Repeated bending | EN 187000, m.507 | IEC 60794-1-2-E6 | 30 cycles [(20xD), 1kg] |